Skip to menu Skip to content

Motor Characteristic Test

Standard :

  • IEC / EN 60034 / UL 1004

Test Clause :

  • motor input, load characteristic, efficiency test etc.

Test Facility Rating :

 
Type \ RatingTourque
(Max)
Power(Max)r/min
5minContinuous
HD-500 850 mmNㆍm 400W 80W 25000
HD-700 3.1 Nㆍm 700W 150W 25000
HD-800 14.0 Nㆍm 2,800W 1,800W 12000
HD-815 28.0 Nㆍm 7,000W 6,000W 12000
Motor Characteristic Test

* One-stop service with dustproof and water facility

Test on Household Equipment

Dustproof and Waterproof testt

Standard :

  • IEC 60529, IEC / EN 60034-5
  • JIC C 0920

Test Clause :

  • 1 : Dustproof
  • 2 : Waterproof

Test Classification : IP68

  • IP5x, IP6x : 2 ~ 8 h
  • IPx1 ~ IPx8 : at least 3min ~ at customer’s spec

* Notice of the Ministry of Labor No. 2008-75 (safety certification of duty about dangerous machinery)

Limited Short Circuit Test (240V / 200V)

Standard :

  • CSA C22.2 UL 60065, UL 60950

Test Facility Rating :

 
Transformer3 Load
CapacityTap (V)R LoadRL Load
(COS@)
500 kVA 220
230
460
200 A 200 A
(0.45/0.65/0.75)

* One-stop service with SMPS test and 200A limited short circuit

Limited Short Circuit Test (240V / 200V)